HYLC-0818 Smart Li-ion Charger
|
|
|
Item
|
|
Specification
|
Remark
|
|
Input
|
|
1
|
Rating Input Volt
|
V(AC)
|
100~240V 50/60Hz
|
|
|
2
|
Input volt range
|
V(AC)
|
90~264V
|
|
|
3
|
Rating input Current
|
mA
|
0.3Arms
|
INPUT: 220V OUTPUT: Full load
|
|
4
|
Max Input Power
|
W
|
20
|
|
|
Output
|
|
5
|
Rating output volt
|
V (DC)
|
8.4V
|
|
|
6
|
Ouput volt range
|
V (DC)
|
6~8.5VDC
|
|
|
7
|
Fit for
|
Ah
|
7.2V LI-ION
|
|
|
8
|
CC Charging current
|
A
|
1.7±10%A
|
|
|
10
|
CV charging volt
|
V
|
8.4±0.1V
|
|
|
|
Finished charging current
|
A
|
<0.2A
|
|
|
11
|
Max charging time
|
hour
|
5
|
Full 4000mAh
|
|
12
|
Max output power
|
W
|
15
|
|
|
13
|
Hold-on time
|
ms
|
20
|
INPUT: 220V OUTPUT: Full load
|
|
14
|
Ripple current
|
mA
|
50
|
INPUT: 220V OUTPUT: Full load
|
|
15
|
Fast/Trickle charging Switch
|
|
V≥8.3V+I<0.2A
|
|
|
16
|
LED
|
|
Red:Fast charging
Green: Finished
|
|
|
17
|
Output Short-circuit protect
|
-
|
Yes
|
Short-circuit Current<2A
|
|
19
|
Efficiency
|
%
|
>80%
|
INPUT: 220V OUTPUT: Full load
|
|
Environment
|
|
20
|
Operation Tem
|
℃
|
-10~+40
|
Full load & natural convection
|
|
21
|
Operation Hum
|
%RH
|
<90
|
Relative humidity, non-condensing.
|
|
22
|
Storage Tem
|
℃
|
-40~+70
|
|
|
23
|
Storage Hum
|
%RH
|
0~+95
|
Relative humidity, non-condensing.
|
|
24
|
Cooling
|
-
|
Natural convection
|
|
|
25
|
Tem coefficient
|
%
|
Less than 5
|
|
|
26
|
Vibration Resistance
|
G
|
5MM/50HZ/600S
5
|
Non-operating condition.
|
|
27
|
Impact Resistance
|
G
|
1m,3 times
|
Non-operating condition.
|
|
Mechanical
|
|
28
|
Net Weight
|
g
|
about 300
|
|
|
29
|
Size
|
mm
|
or 150*68*39
|
Casing only
|
|
30
|
Contact connector
|
-
|
AC
|
Output
|
|
Safety
|
|
31
|
Max tem rise
|
℃
|
<20 on casing
|
At any line and Max.Load
|
|
32
|
Safety
|
-
|
GB4943 EN60950 UL1950
|
|
|
33
|
EMC
|
-
|
EN55022 B
|
|
|
34
|
MTBF
|
hrs
|
30000
|
|
|
35
|
ESD
|
KV
|
8.0
|
|
|
36
|
Hi-Pot Insulation
|
V
|
I/p to o/p:3000(1 min.)
|
For final unit,cut-off currentr=10mA
|